Industrial rectifiers for substations.

NPT designs and manufactures industrial rectifiers for substations — rated voltages of 24, 48, 110, 125, and 220 VDC, with output currents of up to 2,000 A.

Explore the CIB family
NPT CIB.S modular switched rectifier in an industrial enclosure
CIB.S
DC voltages
24 / 48 / 110 / 125 / 220 VDC
Capacity
up to 2.000 A
Technologies
Switched / Thyristor-based

Maximum ranges documented for the CIB family; configuration depends on product and project requirements.

Engineering by requirement

The rectifier is born from your requirement.

Every direct-current system has its own needs. That’s why NPT develops the rectifier’s configuration based on the application’s real data — considering voltage, current, power, AC supply, battery bank, loads, redundancy, supervision, communication, and construction characteristics.

The result is equipment sized for the project's actual requirements, avoiding oversized, undersized, or standardized configurations that limit the application.

We do not adapt the project to the product.
We configure the product for the project.

Tell us your system requirements, and our team will help define the appropriate configuration.

01

Customer requirement

Application, load, and installation environment of the DC system.

02

Voltage · Current · Power

Electrical parameters defined based on the actual system.

03

Architecture · Redundancy · Protections

Topology defined according to load criticality.

04

Format · Supervision · Communication

Physical configuration and integration into the operating environment.

NPT rectifier configured
Electrical

Electrical parameters

  • DC voltage
  • Current
  • Power
  • AC supply
  • Battery bank
  • Load profile
Architecture

System architecture

  • Switched or thyristor-based
  • Modularity
  • Redundancy
  • Distribution
  • Protection
  • Expansion as the project requires
Construction

Physical configuration

  • Enclosure
  • Format
  • Dimensions
  • Internal layout
  • Maintenance accessibility
  • Integration into the installation environment
Supervision

Supervision and integration

  • Alarms
  • Local indication
  • Communication interfaces
  • Integration into the operating environment
  • Features according to family and configuration
How it works

From the AC grid to the critical load, without interruption

The rectifier converts AC mains power into stable direct current, supplying the DC bus and keeping the battery bank charged. If the mains supply fails, the battery takes over, and the inverter converts that energy back into AC when the project includes AC loads. Continuity of critical loads depends on the battery-bank sizing and system architecture defined for the project.

01

AC grid

Primary utility supply

220 to 480 V AC
02

Rectifier

CIB.S · CIB.SP · CIB.T — converts AC into stable DC

24 / 48 / 110 / 125 / 220 VDC
03

DC bus

Stabilized direct-current distribution

Also feeds critical loads directly in DC
04

Battery bank

Kept on float charge, takes over if the grid fails

Carga flutuante — indicação ilustrativa
05

Inverter

Converts DC back into AC, when the project has AC loads to feed

06

Critical loads

Lighting, control, and telecom without noticing the transition

Alternating current (AC)Direct current (DC)Follow the numbered sequence 01 → 06
Technology

The choice depends on the requirement.

Switched and thyristor-based technologies solve the same problem — converting AC into stable DC — with different trade-offs in efficiency, power range, and robustness.

Compare technologies and specify
Switched (high frequency)

CIB.S and CIB.SP

High-frequency rectifier modules with higher power density and a modular architecture that allows structuring redundant configurations — suited for systems where energy efficiency and maintenance flexibility are a priority.

Thyristor-based

CIB.T

A proven technology for high direct currents, with operational robustness — suited for large industrial plants and substations.

In-house manufacturing

From engineering to delivery, without intermediaries

Every CIB rectifier is designed, assembled, and tested at NPT’s own plant in the Ipiranga district of São Paulo — with direct control over engineering, assembly, integration, and testing.

Linha de fabricação de retificadores industriais NPT no bairro do Ipiranga, São Paulo
NPT’s own plant in the Ipiranga district, São Paulo
Painel de retificador NPT com instrumentação frontal, pronto para expedição
Interior de painel NPT com placas de controle, contatores e fiação organizada
Módulos tiristorizados e transformadores montados em gabinete duplo NPT
Painel de distribuição CC NPT com chaves seccionadoras e IHM de supervisão
Painel de distribuição CC NPT de maior porte com tela de supervisão embutida
Interior de painel de distribuição NPT com barramentos, fusíveis e transformador
  1. 01

    Engineering

    Technical specification of the rectifier based on the load.

  2. 02

    Assembly

    Integration of modules, panel, and instrumentation.

  3. 03

    Integration

    Cabling, local supervision, and communication.

  4. 04

    Testing

    Functional validation before shipment to the customer.

  5. 05

    Delivery

    Equipment ready for field commissioning.

Project cycle

From requirement to operation

We accompany the rectifier through every stage of the direct-current system’s life cycle.

  1. 01

    Size

    Survey of the system’s load, voltage, and current.

  2. 02

    Design

    Definition of technology, architecture, and redundancy.

  3. 03

    Manufacture

    Rectifier production at our own plant in the Ipiranga district.

  4. 04

    Test

    Functional testing before leaving the factory.

  5. 05

    Operate

    Field commissioning and energization.

  6. 06

    Support

    Training and after-sales technical support.

Applications

Where NPT rectifiers operate

  • Power substations01
  • DC auxiliary circuits02
  • Telecommunications systems03
  • Industrial plants04
  • Critical infrastructure05
  • Power generation06
Projects and track record

Rectifiers operating in critical environments.

Throughout the NPT line’s track record, direct-current power systems have been applied in power utilities, rail transit systems, generation, and critical infrastructure.

Aerial view of the Cachoeira Dourada Hydroelectric Plant, operated by ENEL Green Power
Power generation

ENEL GREEN POWER

Cachoeira Dourada Hydroelectric Plant

110-125 VDC / 200 A thyristor-based system for the Cachoeira Dourada hydroelectric plant.

Thyristor-based direct-current power system for the Cachoeira Dourada Hydroelectric Plant, with three-phase input at 380-400 VAC / 60 Hz and output at 110-125 VDC / 200 A, dedicated to the reliability of the generation plant’s essential systems.

110-125 VDC
200 A
380-400 VAC three-phase · 60 Hz
  • Thyristor-based
LIGHT’s Fundão substation, with a direct-current power system
Energy utility

LIGHT

Fundão Substation

125 VDC / 100 A thyristor-based system for the Fundão substation.

Thyristor-based direct-current power system for the Fundão substation, with three-phase input at 220 VAC / 60 Hz and output at 125 VDC / 100 A, dedicated to the essential systems of the utility’s operation.

125 VDC
100 A
220 VAC three-phase · 60 Hz
  • Thyristor-based
Direct-current system installation at the Henry Borden Power Plant, EMAE
Power generation

EMAE

Henry Borden Power Plant

125 and 250 VDC for the Henry Borden power plant.

Direct-current power systems of 125 VDC and 250 VDC for the Henry Borden power plant, including manufacturing, installation, commissioning, and the respective distribution panels.

125 VDC
250 VDC
  • Manufacturing
  • Installation
  • Commissioning
  • Distribution panels
Rio Metro direct-current substation
Mobility / metro-rail

Metrô Rio

125 VDC thyristor-based and switched systems for Lines 1 and 2 of Rio Metro.

Renewal of the direct-current power systems for the auxiliary and primary substations of Rio Metro Lines 1 and 2: thyristor-based solutions at 125 VDC / 100 A and 35 A, and switched solutions at 125 VDC / 35 A, with input at 220 VAC or 450 VAC.

125 VDC
100 A
35 A
220 VAC or 450 VAC
  • Thyristor-based
  • Switched
Why NPT

Focus on direct current

01

Focus

We design exclusively direct-current rectification systems.

02

Manufacturing

In-house production at our Ipiranga plant, São Paulo.

03

Engineering

Technical specification based on the customer’s load and DC system.

04

Technology

Switched and thyristor-based architectures for different application profiles.

05

Testing

Functional validation of every unit before shipping.

06

Support

Support from project to operation, without intermediaries.

Group

NPT is part of MACH Capital, the group that also controls POWER.

Both companies share a common technical origin in the Brazilian power sector, but today have clearly specialized roles: POWER in substation automation, protection, control, supervision, and retrofit; NPT in industrial rectifiers and direct-current systems.

Discover NPT’s history

Bring NPT to your market. Representatives, resellers, and technical partners can develop opportunities with NPT.

Become an NPT partner

Need to specify a rectifier?

Tell our team the voltage, current, and application of your project. We’ll get back to you with the right technical configuration for your direct-current system.