NPT
Projects

Direct current in operation.

Rectifiers and DC power systems applied to utilities, generation, mobility, and other critical infrastructure.

Historical archive · NPT track record

The brand changed. The experience remained.

Some of these projects were still supplied under the POWER identity, before NPT was consolidated as a brand specialized in rectifiers and direct-current systems.

Aerial view of the Cachoeira Dourada Hydroelectric Plant, operated by ENEL Green Power
Power generation

ENEL GREEN POWER

Cachoeira Dourada Hydroelectric Plant

110-125 VDC / 200 A thyristor-based system for the Cachoeira Dourada hydroelectric plant.

Thyristor-based direct-current power system for the Cachoeira Dourada Hydroelectric Plant, with three-phase input at 380-400 VAC / 60 Hz and output at 110-125 VDC / 200 A, dedicated to the reliability of the generation plant’s essential systems.

110-125 VDC
200 A
380-400 VAC three-phase · 60 Hz
  • Thyristor-based
LIGHT’s Fundão substation, with a direct-current power system
Energy utility

LIGHT

Fundão Substation

125 VDC / 100 A thyristor-based system for the Fundão substation.

Thyristor-based direct-current power system for the Fundão substation, with three-phase input at 220 VAC / 60 Hz and output at 125 VDC / 100 A, dedicated to the essential systems of the utility’s operation.

125 VDC
100 A
220 VAC three-phase · 60 Hz
  • Thyristor-based
Direct-current system installation at the Henry Borden Power Plant, EMAE
Power generation

EMAE

Henry Borden Power Plant

125 and 250 VDC for the Henry Borden power plant.

Direct-current power systems of 125 VDC and 250 VDC for the Henry Borden power plant, including manufacturing, installation, commissioning, and the respective distribution panels.

125 VDC
250 VDC
  • Manufacturing
  • Installation
  • Commissioning
  • Distribution panels
Rio Metro direct-current substation
Mobility / metro-rail

Metrô Rio

125 VDC thyristor-based and switched systems for Lines 1 and 2 of Rio Metro.

Renewal of the direct-current power systems for the auxiliary and primary substations of Rio Metro Lines 1 and 2: thyristor-based solutions at 125 VDC / 100 A and 35 A, and switched solutions at 125 VDC / 35 A, with input at 220 VAC or 450 VAC.

125 VDC
100 A
35 A
220 VAC or 450 VAC
  • Thyristor-based
  • Switched
CISCEA technical room with a direct-current power system
Aeronautical infrastructure

CISCEA

125 VDC switched system for communication, radar, and technical rooms.

Switched direct-current power systems for VHF stations, radars, and technical rooms under CRCEA-SE management, including detachments and the headquarters installed at Congonhas Airport.

125 VDC
  • Switched
Direct-current power panel installed at Elektro
Energy utility

Elektro

125 VDC for Elektro’s auxiliary systems.

Project with a direct-current power solution at 125 VDC and 35 A, with a rated input of 220 VAC, intended for continuous and stabilized supply to the operation’s auxiliary systems.

125 VDC
35 A
220 VAC
Accumulated experience

Other projects from our track record.

Direct-current system installed at CELPE
Power distribution

CELPE

Two DC architectures for CELPE’s critical applications.

Direct-current power systems at 125 VDC / 75 A and 48 VDC / 150 A, sized for the utility’s critical applications.

125 VDC
48 VDC
75 A
150 A
Direct-current system installed at COELBA
Power distribution

COELBA

125 VDC and 48 VDC for COELBA’s essential systems.

Systems at 125 VDC / 75 A and 48 VDC / 150 A, intended for the stable supply of the utility’s essential systems.

125 VDC
48 VDC
75 A
150 A
Direct-current system installed at COSERN
Power distribution

COSERN

DC power for COSERN’s critical applications.

Systems at 125 VDC / 75 A and 48 VDC / 150 A, applied to reinforce the availability of the operation’s critical loads.

125 VDC
48 VDC
75 A
150 A
Direct-current system installed at São Paulo Metro
Mobility / metro-rail

Metrô SP

125 VDC for the expansion of Line 15-Prata.

Systems at 125 VDC for Boa Esperança, Jacu-Pêssego, and Pátio Ragueb Chohfi stations on Line 15-Prata, with expansion to São Lucas and the section up to Jardim Colonial.

125 VDC
Direct-current system installed at CPTM SP
Mobility / rail

CPTM SP

125 VDC across four CPTM stations.

Systems at 125 VDC applied to the Engenheiro Goulart, Comendador Ermelino, Manoel Feio, and Calmon Viana stations, supporting the continuity of rail operations.

125 VDC
Facade of the Maxion Iochpe industrial plant
Automotive industry

Maxion Iochpe

CIB.S rectifier, 125 VDC / 100 A, for an industrial plant.

CIB.S rectifier at 125 VDC / 100 A supplied for Maxion Iochpe’s industrial plant, ensuring continuous and stable power for the operation’s essential systems.

125 VDC
100 A

Different voltages. Different applications. The same specialization in direct current.

48 VDC125 VDC250 VDC35 A75 A150 A

Does your project also need a dedicated DC system?

Tell our team the voltage, current, and application of your project. We’ll get back to you with the right technical configuration.